Experts in: Load, Force, Weight, Torque, Pressure, Displacement and Position Measurement

Dome Top Column Load Cell | Canister Load Cell | CCDDT

The CCDDT series of dome top column load cells are designed to make compression load measurements for general use or in permanent outdoor installations.

Further applications include hydraulic press calibration, pile force measurement, jack force measurement, centre of gravity measurement systems and structural proof testing. Verification standard versions are available suitable for use in laboratories.

Standard capacities for the CCDDT dome top column load cell range from 2 tonnes up to 1000 tonnes higher capacity versions are available on request.

The dome top column load cell design can be readily modified to provide higher integrity where environmental conditions are particularly arduous such as in marine and offshore applications.  IP68 fully submersible versions can be offered where such conditions prevail.  It is also possible to manufacture low-height versions if space is at a premium.

A high accuracy version of the CCD column load cell is available for use in verification and calibration systems as a reference standard.

PDF Icon Datasheet


Associated Products

TR150 Handheld Digital Indicator     TR150 Handheld Digital Indicator
Intuitive4-L Panel-Mount Digital Indicator     Intuitive4-L Panel-Mount Indicator
FUSION Large Digit Wall-Mount Digital Indicator     FUSION Large Digital Indicator
T24-HA Wireless Telemetry Indicator     T24 Wireless Telemetry Range
DSC-USB Strain Gauge Digitiser      DSC-USB USB Signal Digitiser
ICA Miniature Strain Gauge Amplifier      ICA Miniature Strain Gauge Amplifier
SGA Analogue Strain Gauge Amplifier     SGA Signal Conditioner/Amplifier


Quick Enquiry Form

Name:

Email Address or Phone No:

Your Enquiry:


CCD Column Load Cell

 

  • Capacities: 0-2te up to 0-1000te

  • Output: 1.5mV/V

  • Sealed to IP67 (IP68 submersible versions available)
  • Stainless Steel Construction

  • Optional Amplifier Output & Integral Connector
  • Can be Supplied with Loading Cap & Mounting Base CCDDT Column Load Cell Outline Drawing

MODEL
Capacity (t)
H
ěD
T
S
ØB
CCDDT
2, 5
41
31
M3
5
20
CCDDT
10, 25
75
50
M4
8
34
CCDDT
50
103
88
M4
10
50
CCDDT
100
153
100
M5
12
70
CCDDT
200
180
125
M6
n/a
78
CCDDT
300
185
138
n/a
n/a
n/a
CCDDT
500
250
165
n/a
n/a
n/a
CCDDT
750
350
198
n/a
n/a
n/a
CCDDT
1000
400
276
n/a
n/a
n/a