Experts in: Load, Force, Weight, Torque, Pressure, Displacement and Position Measurement

Submersible In-Line Tension & Compression Load Cell | DDEN

The DDEN series of submersible in-line load cells can be used in both tension and compression and are specially designed for applications where load or force needs to be measured underwater, or in areas subject to high humidity or the risk of flooding.

The submersible load cell is sealed using 'O' rings to provide integrity at depths up to 10 metres as standard, with greater depths possible if the appropriate modifications are made to the design.  The standard model is currently being used in various applications including wave tank measurement systems and mooring buoy cable tension monitoring.

The DDENA version is fitted with an ICA Series Load Cell Amplifier to provide a high-level analogue output, commonly 0-5Vdc, 0-10Vdc, ±10Vdc or 4-20mA, which is suitable for use with most data acqusition and control systems.  An RS485 digital output is also possible by fitting the DCell Load Cell Digitiser in place of the ICA.

Customised versions of the DDEN submersible load cell can be designed to meet your specific requirements.  Please contact our experience sales engineers to discuss your needs either by using the form below, or by phone on +44 (0) 1189 817339, we will be happy to help.

PDF Icon Datasheet


Associated Products

TR150 Handheld Digital Indicator     TR150 Handheld Digital Indicator
Intuitive4-L Panel-Mount Digital Indicator     Intuitive4-L Panel-Mount Indicator
T24-HA Wireless Telemetry Indicator     T24 Wireless Telemetry Range
DSC-USB Strain Gauge Digitiser      DSC-USB USB Signal Digitiser
ICA Miniature Strain Gauge Amplifier      ICA Miniature Strain Gauge Amplifier
SGA Analogue Strain Gauge Amplifier     SGA Signal Conditioner/Amplifier


Quick Enquiry Form

Name:

Email Address or Phone No:

Your Enquiry:


DDEN Submersible In-Line Load Cell

 

  • Capacities: 0-250N up to 0-50kN

  • Output: 0.75mV/V to 2mV/V

  • Fully Submersible: IP68 to 10m

  • Accuracy: <±0.15%/RC (0.05% typical)

  • Optional Integral Amplifier
DDEN Submersible In-Line Load Cell Outline Drawing
Model
Capacity
A
B
C
ěD
E
DDEN
0-250N up to 0-20kN
67
15
35
44
M12x1.75
DDEN
0-50kN
71
18
35
44
M16x2.0
DDENA
0-250N up to 0-20kN
67
15
35
44
M12x1.75
DDENA
0-50kN
71
17
37
50
M16x2.0